{"id":9716,"date":"2026-03-12T17:10:26","date_gmt":"2026-03-12T21:10:26","guid":{"rendered":"https:\/\/assuredautomation.com\/news-and-training\/?p=9716"},"modified":"2026-03-12T17:10:27","modified_gmt":"2026-03-12T21:10:27","slug":"designing-valve-automation-for-high-cycle-applications","status":"publish","type":"post","link":"https:\/\/assuredautomation.com\/news-and-training\/designing-valve-automation-for-high-cycle-applications\/","title":{"rendered":"Designing Valve Automation for High-Cycle Applications"},"content":{"rendered":"\n<figure class=\"wp-block-image aligncenter size-large\" style=\"margin-bottom:var(--wp--preset--spacing--40)\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"575\" src=\"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2026\/03\/March_blog1_featured_image-1024x575.webp\" alt=\"valve automation for high-cycle applications\" class=\"wp-image-9717\" srcset=\"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2026\/03\/March_blog1_featured_image-1024x575.webp 1024w, https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2026\/03\/March_blog1_featured_image-300x169.webp 300w, https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2026\/03\/March_blog1_featured_image-768x431.webp 768w, https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2026\/03\/March_blog1_featured_image.webp 1280w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>Valve automation for high-cycle applications places unique demands on valves, actuators, and control components. In many automated processes, valves may open and close <strong>thousands of times per day<\/strong>, making reliability and mechanical durability critical.<\/p>\n\n\n\n<p>These environments are common in many industries, including:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Chemical processing<\/li>\n\n\n\n<li>Emissions control systems<\/li>\n\n\n\n<li>Automated packaging lines<\/li>\n\n\n\n<li>Semiconductor manufacturing equipment<\/li>\n\n\n\n<li>Test benches and laboratory systems<\/li>\n<\/ul>\n\n\n\n<p>In some industrial systems, the cycling demand can be extremely high. For example, valves used in <strong>regenerative thermal oxidizers (RTOs)<\/strong> may operate <strong>more than 200,000 cycles per year<\/strong> while maintaining reliable sealing performance. (<em>Source \u2013 <a href=\"https:\/\/www.chemengonline.com\/critical-components-in-regenerative-thermal-oxidizers-high-cycle-valves\/\" target=\"_blank\" rel=\"noreferrer noopener\">Chemical Engineering<\/a><\/em>).<\/p>\n\n\n\n<p>Under these conditions, poorly designed automation systems can fail prematurely. Common causes include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Incorrect actuator sizing<\/li>\n\n\n\n<li>Unsuitable valve types<\/li>\n\n\n\n<li>Seal materials that wear quickly<\/li>\n\n\n\n<li>Control accessories not designed for frequent switching<\/li>\n<\/ul>\n\n\n\n<p>Designing valve automation for high-cycle applications, therefore, requires careful evaluation of the entire system\u2014not just the valve itself. Engineers must consider valve selection, actuator performance, materials of construction, and overall system integration to ensure reliable long-term operation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What Defines Valve Automation for High-Cycle Applications?<\/h2>\n\n\n\n<p>Not every automated valve application qualifies as \u201chigh-cycle.\u201d In many industrial processes, valves may operate only a few times per hour or even per day. High-cycle environments are different. The valve and actuator must operate repeatedly, often with little downtime between cycles. Engineers typically consider an application high-cycle when the valve must operate thousands of times per day or hundreds of thousands of cycles per year.<\/p>\n\n\n\n<p>Typical examples include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Automated batching and dosing systems<\/li>\n\n\n\n<li>Packaging and filling equipment<\/li>\n\n\n\n<li>Automated test stands<\/li>\n\n\n\n<li>Emissions control systems such as RTOs<\/li>\n\n\n\n<li>Semiconductor and electronics manufacturing tools<\/li>\n<\/ul>\n\n\n\n<p>In these environments, the automation system must handle continuous mechanical motion. Each cycle introduces wear to multiple components, including:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Valve seats and seals<\/li>\n\n\n\n<li>Actuator gears or pistons<\/li>\n\n\n\n<li>Stem packing and bearings<\/li>\n\n\n\n<li>Solenoid valves and control accessories<\/li>\n<\/ul>\n\n\n\n<p>Over time, even small inefficiencies can accumulate. Excessive torque requirements, improper actuator sizing, or unsuitable materials may shorten system life.<\/p>\n\n\n\n<p>For this reason, engineers designing valve automation for high-cycle applications often focus on equipment specifically built to tolerate frequent operation.<\/p>\n\n\n\n<p>Examples include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/assuredautomation.com\/actuated-ball-valves\/\">Actuated 2-way<\/a> and <a href=\"https:\/\/assuredautomation.com\/3-way-ball-valves\/\">3-way ball valves<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/assuredautomation.com\/pneumatic-valve-actuators\/\">Pneumatic actuator systems<\/a> designed for frequent operation<\/li>\n\n\n\n<li>Valve designs optimized for rapid cycling, such as coaxial valves, include the <a href=\"https:\/\/assuredautomation.com\/VA\/\">VA Series<\/a><\/li>\n<\/ul>\n\n\n\n<p>A U.S. Gulf Coast refinery with a hydrogen PSA unit experienced years of chronic valve failures that repeatedly reduced hydrogen production \u2014 directly impacting downstream operations. Only a complete valve replacement program resolved the problem. <em>(Source: <\/em><a href=\"https:\/\/www.chemicalprocessing.com\/processing-equipment\/fluid-handling\/article\/11296497\/valve-upgrades-take-pressure-off-psa-unit-chemical-processing\" target=\"_blank\" rel=\"noreferrer noopener\"><em>Chemical Processing<\/em><\/a><em>)<\/em><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Selecting the Right Valve Type for High-Cycle Valve Automation<\/h2>\n\n\n\n<p>Valve selection is one of the most important decisions when designing valve automation for high-cycle applications. Some valves are better suited for continuous cycling because they minimize friction, reduce wear on internal components, and maintain sealing performance over long operating periods.<\/p>\n\n\n\n<p>Engineers typically evaluate several factors when selecting valves for high-cycle automation:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Number of expected cycles per year<\/li>\n\n\n\n<li>Pressure and temperature conditions<\/li>\n\n\n\n<li>Fluid compatibility<\/li>\n\n\n\n<li>Response speed requirements<\/li>\n\n\n\n<li>Maintenance accessibility<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Ball Valves<\/h3>\n\n\n\n<p>Ball valves are widely used in automated systems because they provide:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Simple quarter-turn operation<\/li>\n\n\n\n<li>Reliable shutoff<\/li>\n\n\n\n<li>Compact automation packages<\/li>\n<\/ul>\n\n\n\n<p>Integrated packages, such as the <a href=\"https:\/\/assuredautomation.com\/VA\/\">VA Series<\/a>, combine the valve, actuator, and mounting hardware into a compact assembly designed for reliable automation.<\/p>\n\n\n\n<p><strong>Coaxial Valves<\/strong><\/p>\n\n\n\n<p>Coaxial valves can provide important advantages. These valves feature a balanced internal structure that reduces friction during operation.<\/p>\n\n\n\n<p>Benefits may include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Fast response time<\/li>\n\n\n\n<li>High cycle capability<\/li>\n\n\n\n<li>Reduced actuator force requirements<\/li>\n<\/ul>\n\n\n\n<p>Products such as the <a href=\"https:\/\/assuredautomation.com\/VA\/\">VA Series \u201cValve + Actuator\u201d on-off valves<\/a> are often used in automated test systems, gas handling systems, and other demanding environments. <\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Angle Seat Valves<\/h3>\n\n\n\n<p><a href=\"https:\/\/assuredautomation.com\/anglevalve\/\">Angle Seat Valves<\/a> are commonly used in steam, air, and fluid control applications where frequent operation is required.<\/p>\n\n\n\n<p>Advantages include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Strong flow capacity<\/li>\n\n\n\n<li>Durable piston-style actuation<\/li>\n\n\n\n<li>Long service life in repetitive applications<\/li>\n<\/ul>\n\n\n\n<p>Selecting the appropriate valve type helps reduce mechanical stress on the automation system. However, valve design alone does not determine system reliability. The actuator must also be properly selected and sized to handle the expected cycling demands.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Actuator Selection Considerations for High-Cycle Valve Automation<\/h2>\n\n\n\n<p>Actuator selection plays a major role in the reliability of valve automation for high-cycle applications. Even when the correct valve is chosen, an improperly selected actuator can shorten system life or create unnecessary maintenance problems.<\/p>\n\n\n\n<p>High-cycle operation means the actuator must deliver <strong>consistent torque and speed across thousands\u2014or even millions\u2014of cycles<\/strong>. Engineers should evaluate several factors when selecting actuators for these demanding environments.<\/p>\n\n\n\n<p>Key considerations include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Required torque output<\/li>\n\n\n\n<li>Actuator duty cycle rating<\/li>\n\n\n\n<li>Response speed<\/li>\n\n\n\n<li>Air or power consumption<\/li>\n\n\n\n<li>Operating environment<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Pneumatic Actuators<\/h3>\n\n\n\n<p><a href=\"https:\/\/assuredautomation.com\/pneumatic-valve-actuators\/\">Pneumatic actuators<\/a> are widely preferred for high-cycle automation because they are mechanically simple and capable of rapid operation.<\/p>\n\n\n\n<p>Advantages include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Fast actuation speeds<\/li>\n\n\n\n<li>High cycle durability<\/li>\n\n\n\n<li>Relatively simple internal construction<\/li>\n\n\n\n<li>Ability to operate in harsh environments<\/li>\n<\/ul>\n\n\n\n<p>These characteristics make pneumatic actuators suitable for applications such as automated production equipment, test systems, and fluid handling processes.<\/p>\n\n\n\n<p>For example, rack-and-pinion pneumatic actuators are commonly used with quarter-turn valves in automated systems because they provide reliable torque output and repeatable operation.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Electric Actuators<\/h3>\n\n\n\n<p><a href=\"https:\/\/assuredautomation.com\/electric-valve-actuators\/\">Electric actuators<\/a> can also be used in automated valve systems, particularly when:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Precise positioning is required<\/li>\n\n\n\n<li>Compressed air is unavailable<\/li>\n\n\n\n<li>Cycle speeds are moderate<\/li>\n<\/ul>\n\n\n\n<p>However, electric actuators may not always be the first choice in extremely high-cycle environments due to heat generation and duty cycle limitations.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Proper Actuator Sizing<\/h2>\n\n\n\n<p>Incorrect actuator sizing is one of the most common causes of failure in automated valve systems.<\/p>\n\n\n\n<p>If an actuator is <strong>undersized<\/strong>, it may struggle to overcome the torque required by the valve, leading to premature wear or incomplete valve movement.<\/p>\n\n\n\n<p>If it is <strong>oversized<\/strong>, the system may cycle too aggressively, increasing mechanical stress on the valve and automation components.<\/p>\n\n\n\n<p>Assured Automation\u2019s <a href=\"https:\/\/assuredautomation.com\/pneumatic-valve-actuators\/\">C Series and F Series rack and pinion pneumatic actuators<\/a> are rated for up to one million cycles \u2014 making them well-suited for the sustained mechanical demands of high-cycle environments.<\/p>\n\n\n\n<p>Actuator selection is only part of the equation. High-cycle environments also place significant stress on seals, seats, and other wear components. Choosing the right materials and design features can help extend system life and reduce maintenance.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Control Accessories Matter in High-Cycle Valve Automation<\/h2>\n\n\n\n<p>When engineers design valve automation for high-cycle applications, the focus is often on the valve and actuator. However, smaller automation components, such as solenoid valves, limit switches, and position feedback devices, also operate each time the valve cycles.<\/p>\n\n\n\n<p>In high-cycle environments, these accessories may switch hundreds of thousands of times per year, making durability and reliability just as important as the valve itself.<\/p>\n\n\n\n<p>Engineers should evaluate the cycle life, switching speed, environmental ratings, and control system compatibility of these components. Selecting properly rated accessories helps ensure consistent actuator performance and reliable position feedback in demanding applications.<\/p>\n\n\n\n<p>Assured Automation offers a range of <a href=\"https:\/\/assuredautomation.com\/valve-accessories\/index.php\">automation accessories<\/a> for automated valve systems, including solenoid valves and limit switch boxes.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Design Checklist for High-Cycle Valve Automation<\/h2>\n\n\n\n<p>Engineers evaluating valve automation for high-cycle applications should consider several important factors during system design:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Expected number of cycles per day or per year<\/li>\n\n\n\n<li>Selecting valve types suited for frequent operation<\/li>\n\n\n\n<li>Proper actuator sizing and torque margins<\/li>\n\n\n\n<li>Automation accessories capable of frequent switching<\/li>\n\n\n\n<li>Reliable system integration and installation alignment<\/li>\n<\/ul>\n\n\n\n<p>When these factors are addressed early in the design process, automated valve systems are far more likely to achieve reliable long-term performance.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Talk to the Valve Automation Experts<\/h2>\n\n\n\n<p>If you are evaluating automation options for a demanding high-cycle application, the valve automation specialists at <a href=\"https:\/\/assuredautomation.com\/contact.php\">Assured Automation can help.<\/a> Our team can assist with selecting the right valves, actuators, and automation accessories to ensure dependable performance in your specific process.<\/p>\n\n\n\n<p><a href=\"https:\/\/assuredautomation.com\/contact.php\">Contact our valve automation experts<\/a> today to discuss your application requirements.<\/p>\n\n\n<div style=\"background-color:#f6f6f6; font-size:clamp(0.875rem, 0.875rem + ((1vw - 0.2rem) * 0.773), 1.3rem);font-style:normal;font-weight:400;line-height:1.8; border-radius:10px; padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--30);padding-right:var(--wp--preset--spacing--30);margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30);\" class=\"wp-block-post-author has-background\"><div class=\"wp-block-post-author__avatar\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2025\/06\/vinnie_collier-150x150.jpeg\" width=\"96\" height=\"96\" srcset=\"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2025\/06\/vinnie_collier-300x300.jpeg 2x\" alt=\"Vinnie Collier\" class=\"avatar avatar-96 wp-user-avatar wp-user-avatar-96 alignnone photo\" \/><\/div><div class=\"wp-block-post-author__content\"><p class=\"wp-block-post-author__byline\">General Manager<\/p><p class=\"wp-block-post-author__name\">Vinnie Collier<\/p><p class=\"wp-block-post-author__bio\">Vincent \u201cVinnie\u201d Collier is the General Manager of Assured Automation. Since joining the company in 2004, he ascended through the ranks starting in shipping and receiving. Then moving to the shop for technical assembly, and then moving on to sales in 2012. Vinnie then became Sales Manager in 2018 and finally was named General Manager in 2024. With over two decades of hands-on experience, Vinnie brings deep operational insight and leadership to Assured Automation and the valve automation industry as a whole.<\/p><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Valve automation for high-cycle applications places unique demands on valves, actuators, and control components. In many automated processes, valves may open and close thousands of times per day, making reliability and mechanical durability critical. These environments are common in many industries, including: In some industrial systems, the cycling demand can be extremely high. For example, [&hellip;]<\/p>\n","protected":false},"author":12073,"featured_media":9717,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[666,651,665,5,662],"tags":[],"class_list":["post-9716","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-automated-valves","category-coaxial-valves","category-electric-actuators","category-automatednews","category-pneumatic-actuators"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Valve Automation for High-Cycle Applications<\/title>\n<meta name=\"description\" content=\"Designing valve automation for high-cycle applications requires careful valve selection, actuator sizing, and system integration.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/assuredautomation.com\/news-and-training\/designing-valve-automation-for-high-cycle-applications\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Valve Automation for High-Cycle Applications\" \/>\n<meta property=\"og:description\" content=\"Designing valve automation for high-cycle applications requires careful valve selection, actuator sizing, and system integration.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/assuredautomation.com\/news-and-training\/designing-valve-automation-for-high-cycle-applications\/\" \/>\n<meta property=\"og:site_name\" content=\"Assured Automation\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/AssuredAutomation\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-12T21:10:26+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-12T21:10:27+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2026\/03\/March_blog1_featured_image.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1280\" \/>\n\t<meta property=\"og:image:height\" content=\"719\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Vinnie Collier\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@aaValvesMeters\" \/>\n<meta name=\"twitter:site\" content=\"@aaValvesMeters\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Vinnie Collier\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/designing-valve-automation-for-high-cycle-applications\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/designing-valve-automation-for-high-cycle-applications\\\/\"},\"author\":{\"name\":\"Vinnie Collier\",\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/#\\\/schema\\\/person\\\/6e22f690fbfcedcd055bcabb1ec043d6\"},\"headline\":\"Designing Valve Automation for High-Cycle Applications\",\"datePublished\":\"2026-03-12T21:10:26+00:00\",\"dateModified\":\"2026-03-12T21:10:27+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/designing-valve-automation-for-high-cycle-applications\\\/\"},\"wordCount\":1265,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/designing-valve-automation-for-high-cycle-applications\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/March_blog1_featured_image.webp\",\"articleSection\":[\"Automated Valves\",\"Coaxial Valves\",\"Electric actuators\",\"Latest News\",\"Pneumatic Actuators\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/designing-valve-automation-for-high-cycle-applications\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/designing-valve-automation-for-high-cycle-applications\\\/\",\"url\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/designing-valve-automation-for-high-cycle-applications\\\/\",\"name\":\"Valve Automation for High-Cycle Applications\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/designing-valve-automation-for-high-cycle-applications\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/designing-valve-automation-for-high-cycle-applications\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/March_blog1_featured_image.webp\",\"datePublished\":\"2026-03-12T21:10:26+00:00\",\"dateModified\":\"2026-03-12T21:10:27+00:00\",\"description\":\"Designing valve automation for high-cycle applications requires careful valve selection, actuator sizing, and system integration.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/designing-valve-automation-for-high-cycle-applications\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/designing-valve-automation-for-high-cycle-applications\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/designing-valve-automation-for-high-cycle-applications\\\/#primaryimage\",\"url\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/March_blog1_featured_image.webp\",\"contentUrl\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/March_blog1_featured_image.webp\",\"width\":1280,\"height\":719,\"caption\":\"valve automation for high-cycle applications\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/designing-valve-automation-for-high-cycle-applications\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Designing Valve Automation for High-Cycle Applications\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/#website\",\"url\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/\",\"name\":\"Assured Automation\",\"description\":\"Automated and Actuated Valves News and Training\",\"publisher\":{\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/#organization\",\"name\":\"Assured Automation\",\"url\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/wp-content\\\/uploads\\\/2015\\\/03\\\/AA_logo.gif\",\"contentUrl\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/wp-content\\\/uploads\\\/2015\\\/03\\\/AA_logo.gif\",\"width\":201,\"height\":51,\"caption\":\"Assured Automation\"},\"image\":{\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/AssuredAutomation\",\"https:\\\/\\\/x.com\\\/aaValvesMeters\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/assured-automation\",\"https:\\\/\\\/youtube.com\\\/user\\\/assuredautomation\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/#\\\/schema\\\/person\\\/6e22f690fbfcedcd055bcabb1ec043d6\",\"name\":\"Vinnie Collier\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/wp-content\\\/uploads\\\/2025\\\/06\\\/vinnie_collier-150x150.jpeg\",\"url\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/wp-content\\\/uploads\\\/2025\\\/06\\\/vinnie_collier-150x150.jpeg\",\"contentUrl\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/wp-content\\\/uploads\\\/2025\\\/06\\\/vinnie_collier-150x150.jpeg\",\"caption\":\"Vinnie Collier\"},\"description\":\"Vincent \u201cVinnie\u201d Collier is the General Manager of Assured Automation. Since joining the company in 2004, he ascended through the ranks starting in shipping and receiving. Then moving to the shop for technical assembly, and then moving on to sales in 2012. Vinnie then became Sales Manager in 2018 and finally was named General Manager in 2024. With over two decades of hands-on experience, Vinnie brings deep operational insight and leadership to Assured Automation and the valve automation industry as a whole.\",\"sameAs\":[\"https:\\\/\\\/assuredautomation.com\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/vinnie-collier-61b1544a\\\/\"],\"url\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/author\\\/vinnie-collier\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Valve Automation for High-Cycle Applications","description":"Designing valve automation for high-cycle applications requires careful valve selection, actuator sizing, and system integration.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/assuredautomation.com\/news-and-training\/designing-valve-automation-for-high-cycle-applications\/","og_locale":"en_US","og_type":"article","og_title":"Valve Automation for High-Cycle Applications","og_description":"Designing valve automation for high-cycle applications requires careful valve selection, actuator sizing, and system integration.","og_url":"https:\/\/assuredautomation.com\/news-and-training\/designing-valve-automation-for-high-cycle-applications\/","og_site_name":"Assured Automation","article_publisher":"https:\/\/www.facebook.com\/AssuredAutomation","article_published_time":"2026-03-12T21:10:26+00:00","article_modified_time":"2026-03-12T21:10:27+00:00","og_image":[{"width":1280,"height":719,"url":"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2026\/03\/March_blog1_featured_image.webp","type":"image\/webp"}],"author":"Vinnie Collier","twitter_card":"summary_large_image","twitter_creator":"@aaValvesMeters","twitter_site":"@aaValvesMeters","twitter_misc":{"Written by":"Vinnie Collier","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/assuredautomation.com\/news-and-training\/designing-valve-automation-for-high-cycle-applications\/#article","isPartOf":{"@id":"https:\/\/assuredautomation.com\/news-and-training\/designing-valve-automation-for-high-cycle-applications\/"},"author":{"name":"Vinnie Collier","@id":"https:\/\/assuredautomation.com\/news-and-training\/#\/schema\/person\/6e22f690fbfcedcd055bcabb1ec043d6"},"headline":"Designing Valve Automation for High-Cycle Applications","datePublished":"2026-03-12T21:10:26+00:00","dateModified":"2026-03-12T21:10:27+00:00","mainEntityOfPage":{"@id":"https:\/\/assuredautomation.com\/news-and-training\/designing-valve-automation-for-high-cycle-applications\/"},"wordCount":1265,"commentCount":0,"publisher":{"@id":"https:\/\/assuredautomation.com\/news-and-training\/#organization"},"image":{"@id":"https:\/\/assuredautomation.com\/news-and-training\/designing-valve-automation-for-high-cycle-applications\/#primaryimage"},"thumbnailUrl":"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2026\/03\/March_blog1_featured_image.webp","articleSection":["Automated Valves","Coaxial Valves","Electric actuators","Latest News","Pneumatic Actuators"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/assuredautomation.com\/news-and-training\/designing-valve-automation-for-high-cycle-applications\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/assuredautomation.com\/news-and-training\/designing-valve-automation-for-high-cycle-applications\/","url":"https:\/\/assuredautomation.com\/news-and-training\/designing-valve-automation-for-high-cycle-applications\/","name":"Valve Automation for High-Cycle Applications","isPartOf":{"@id":"https:\/\/assuredautomation.com\/news-and-training\/#website"},"primaryImageOfPage":{"@id":"https:\/\/assuredautomation.com\/news-and-training\/designing-valve-automation-for-high-cycle-applications\/#primaryimage"},"image":{"@id":"https:\/\/assuredautomation.com\/news-and-training\/designing-valve-automation-for-high-cycle-applications\/#primaryimage"},"thumbnailUrl":"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2026\/03\/March_blog1_featured_image.webp","datePublished":"2026-03-12T21:10:26+00:00","dateModified":"2026-03-12T21:10:27+00:00","description":"Designing valve automation for high-cycle applications requires careful valve selection, actuator sizing, and system integration.","breadcrumb":{"@id":"https:\/\/assuredautomation.com\/news-and-training\/designing-valve-automation-for-high-cycle-applications\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/assuredautomation.com\/news-and-training\/designing-valve-automation-for-high-cycle-applications\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/assuredautomation.com\/news-and-training\/designing-valve-automation-for-high-cycle-applications\/#primaryimage","url":"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2026\/03\/March_blog1_featured_image.webp","contentUrl":"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2026\/03\/March_blog1_featured_image.webp","width":1280,"height":719,"caption":"valve automation for high-cycle applications"},{"@type":"BreadcrumbList","@id":"https:\/\/assuredautomation.com\/news-and-training\/designing-valve-automation-for-high-cycle-applications\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/assuredautomation.com\/news-and-training\/"},{"@type":"ListItem","position":2,"name":"Designing Valve Automation for High-Cycle Applications"}]},{"@type":"WebSite","@id":"https:\/\/assuredautomation.com\/news-and-training\/#website","url":"https:\/\/assuredautomation.com\/news-and-training\/","name":"Assured Automation","description":"Automated and Actuated Valves News and Training","publisher":{"@id":"https:\/\/assuredautomation.com\/news-and-training\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/assuredautomation.com\/news-and-training\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/assuredautomation.com\/news-and-training\/#organization","name":"Assured Automation","url":"https:\/\/assuredautomation.com\/news-and-training\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/assuredautomation.com\/news-and-training\/#\/schema\/logo\/image\/","url":"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2015\/03\/AA_logo.gif","contentUrl":"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2015\/03\/AA_logo.gif","width":201,"height":51,"caption":"Assured Automation"},"image":{"@id":"https:\/\/assuredautomation.com\/news-and-training\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/AssuredAutomation","https:\/\/x.com\/aaValvesMeters","https:\/\/www.linkedin.com\/company\/assured-automation","https:\/\/youtube.com\/user\/assuredautomation"]},{"@type":"Person","@id":"https:\/\/assuredautomation.com\/news-and-training\/#\/schema\/person\/6e22f690fbfcedcd055bcabb1ec043d6","name":"Vinnie Collier","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2025\/06\/vinnie_collier-150x150.jpeg","url":"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2025\/06\/vinnie_collier-150x150.jpeg","contentUrl":"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2025\/06\/vinnie_collier-150x150.jpeg","caption":"Vinnie Collier"},"description":"Vincent \u201cVinnie\u201d Collier is the General Manager of Assured Automation. Since joining the company in 2004, he ascended through the ranks starting in shipping and receiving. Then moving to the shop for technical assembly, and then moving on to sales in 2012. Vinnie then became Sales Manager in 2018 and finally was named General Manager in 2024. With over two decades of hands-on experience, Vinnie brings deep operational insight and leadership to Assured Automation and the valve automation industry as a whole.","sameAs":["https:\/\/assuredautomation.com\/","https:\/\/www.linkedin.com\/in\/vinnie-collier-61b1544a\/"],"url":"https:\/\/assuredautomation.com\/news-and-training\/author\/vinnie-collier\/"}]}},"_links":{"self":[{"href":"https:\/\/assuredautomation.com\/news-and-training\/wp-json\/wp\/v2\/posts\/9716","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/assuredautomation.com\/news-and-training\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/assuredautomation.com\/news-and-training\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/assuredautomation.com\/news-and-training\/wp-json\/wp\/v2\/users\/12073"}],"replies":[{"embeddable":true,"href":"https:\/\/assuredautomation.com\/news-and-training\/wp-json\/wp\/v2\/comments?post=9716"}],"version-history":[{"count":11,"href":"https:\/\/assuredautomation.com\/news-and-training\/wp-json\/wp\/v2\/posts\/9716\/revisions"}],"predecessor-version":[{"id":9734,"href":"https:\/\/assuredautomation.com\/news-and-training\/wp-json\/wp\/v2\/posts\/9716\/revisions\/9734"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/assuredautomation.com\/news-and-training\/wp-json\/wp\/v2\/media\/9717"}],"wp:attachment":[{"href":"https:\/\/assuredautomation.com\/news-and-training\/wp-json\/wp\/v2\/media?parent=9716"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/assuredautomation.com\/news-and-training\/wp-json\/wp\/v2\/categories?post=9716"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/assuredautomation.com\/news-and-training\/wp-json\/wp\/v2\/tags?post=9716"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}