{"id":8903,"date":"2025-04-16T14:41:27","date_gmt":"2025-04-16T18:41:27","guid":{"rendered":"https:\/\/assuredautomation.com\/news-and-training\/?p=8903"},"modified":"2025-08-19T20:40:04","modified_gmt":"2025-08-20T00:40:04","slug":"simplifying-actuator-sizing-for-quarter-turn-valves-a-practical-guide","status":"publish","type":"post","link":"https:\/\/assuredautomation.com\/news-and-training\/simplifying-actuator-sizing-for-quarter-turn-valves-a-practical-guide\/","title":{"rendered":"Simplifying Actuator Sizing for Quarter-Turn Valves: A Practical Guide"},"content":{"rendered":"\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"600\" src=\"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2025\/04\/Sizing-Actuators.jpg\" alt=\"\" class=\"wp-image-8952\" style=\"width:1100px;height:auto\" srcset=\"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2025\/04\/Sizing-Actuators.jpg 1000w, https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2025\/04\/Sizing-Actuators-300x180.jpg 300w, https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2025\/04\/Sizing-Actuators-768x461.jpg 768w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/figure>\n\n\n\n<p><a href=\"https:\/\/assuredautomation.com\/valve-actuators\/\">Actuator sizing for quarter-turn valves<\/a> may seem simple, but there\u2019s a bit more to it than just matching torque values from a chart against the torque values required by the valve. In fact, it\u2019s one of the most common areas where engineers and buyers make critical mistakes.<\/p>\n\n\n\n<p>At Assured Automation, we\u2019ve helped customers navigate these challenges for over 40 years. This guide explains key sizing principles, how to size valve actuators correctly, what common mistakes to avoid, and how we simplify the process\u2014with tools and support designed to help you make confident decisions.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Why Proper Actuator Sizing Matters<\/h2>\n\n\n\n<p>Actuator sizing affects how efficiently and reliably your system runs, as well as initial costs and operating costs.<\/p>\n\n\n\n<p><strong>Under-sizing Valve Actuators Leads to:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Slow or erratic valve movement<\/li>\n\n\n\n<li>Failure to open or close the valve completely<\/li>\n\n\n\n<li>Delays and\/or downtime in order to replace it with a properly sized actuator<\/li>\n\n\n\n<li>Waste of materials due to failed process results<\/li>\n<\/ul>\n\n\n\n<p><strong>Over-sizing<\/strong> <strong>Valve Actuators Leads to:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Increased initial cost of the actuator <\/li>\n\n\n\n<li>Unnecessarily larger physical size and heavier weight<\/li>\n\n\n\n<li>Increased air consumption thus increasing the cost of energy to operate it for pneumatic actuators<\/li>\n\n\n\n<li>In extreme case where there are many oversized pneumatic actuators in use and\/or with high cycle frequency, oversized actuators may cause the need for a larger capacity compressed air system<\/li>\n\n\n\n<li>Valves with oversized pneumatic actuators will take longer than needed to cycle on the air stroke &#8211; whichever direction that is<\/li>\n\n\n\n<li>Valves with oversized electric actuators will take longer than needed to cycle on both clockwise and counter-clockwise strokes <\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Actuator Sizing Basics for Quarter-Turn Valves<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">It&#8217;s all About the Torque: <br>Output of the Actuator vs. Requirements of the Valve<\/h3>\n\n\n\n<p>When sizing rotary actuators for valve applications, torque is the most important factor. For quarter-turn valves like <a href=\"https:\/\/assuredautomation.com\/actuated-ball-valves\/\">2-way<\/a> and <a href=\"https:\/\/assuredautomation.com\/3-way-ball-valves\/\">3-way ball<\/a>, <a href=\"https:\/\/assuredautomation.com\/butterfly-valves\/\">butterfly<\/a>, and <a href=\"https:\/\/assuredautomation.com\/plug-valves\/\">plug valves<\/a>, the actuator must overcome the valve\u2019s &#8220;break torque&#8221; (the initial force needed to unseat the ball, plug, or disc) and also provide sufficient &#8220;running torque&#8221; throughout the entire stroke.<\/p>\n\n\n\n<p>The core of actuator sizing lies in ensuring that the lowest torque output of the actuator is greater than the highest torque required to actuate the valve.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Actuator Output<\/h4>\n\n\n\n<p class=\"has-primary-color has-text-color has-link-color wp-elements-fe915bd03257145b58b8d1a0f7f5125b\"><strong>IMPORTANT:<\/strong> <strong>Torque Output of an Actuator is NOT Always Constant!<\/strong><\/p>\n\n\n\n<p>Understanding torque curves is essential when selecting between actuator types. <a href=\"https:\/\/assuredautomation.com\/P-pneumatic-actuators\/index.php?p=scotch-yoke-valve-actuators\">Scotch yoke actuators,<\/a> for example, generate non-linear torque\u2014with high torque at the beginning and end of the stroke. This makes them ideal for applications requiring extra force to unseat or reseat the valve (such as resilient-seated butterfly valves or high-pressure ball valves). On the other hand, rack-and-pinion actuators produce a linear torque output. Spring return actuators always deliver less torque at the end of the stroke. This is true on the sir stroke and the spring stroke.<\/p>\n\n\n\n<p>Double acting rack-n-pinion actuators are the only type that have a constant  <\/p>\n\n\n\n<p><strong>Rack-n-pinion Spring-return actuators provide linear decreasing torque in BOTH directions.<\/strong> <br><strong>Air Stroke:<\/strong> As the spring compresses, the resisting force it creates increases, therefore the actuator&#8217;s torque output decreases.<br><strong>Spring Stroke:<\/strong> As the spring expands, the force provided decreases.<\/p>\n\n\n\n<img decoding=\"async\" src=\"\/SVGs\/SR-Rack-n-Pinion-Torque-Curve.svg\" style=\"width:100%;\" \/>\n\n\n\n<p><strong>Scotch Yoke Spring-return actuators provide a curved decreasing torque in BOTH directions.<\/strong> <br><strong>Air Stroke:<\/strong> As the spring compresses, the resisting force it creates increases.<br><strong>Spring Stroke:<\/strong> As the spring expands, the force provided decreases.<br><strong>Both Strokes:<\/strong> the torque is reduced in the middle of the stroke due to the mechanics of a scotch yoke.<\/p>\n\n\n\n<img decoding=\"async\" src=\"\/SVGs\/SR-Scotch-Yoke-Torque-Curve.svg\" style=\"width:100%;\" \/>\n\n\n\n<h4 class=\"wp-block-heading\">Valve Requirements<\/h4>\n\n\n\n<p><a href=\"https:\/\/assuredautomation.com\/valve-actuators\/\">Quarter-turn valves<\/a> operate with a 90-degree rotation to open or close the flow path. While that motion is simple, the forces required to drive it vary considerably based on valve design, media characteristics, media, and system conditions.<\/p>\n\n\n\n<p class=\"has-primary-color has-text-color has-link-color wp-elements-a85c86d585b0c9bed6924ac46e1f4448\"><strong>IMPORTANT:<\/strong> <strong>There Are Usually More than One Torque Value to Consider for a Valve<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Break torque<\/strong> (aka, unseating torque) is the initial force needed to start the valve\u2019s rotation. This can increase considerably in applications where the valve remains in one position for an extended period of time and when the differential pressure is high.<\/li>\n\n\n\n<li><strong>Running torque<\/strong> is the torque required to maintain the movement between its fully open and fully closed positions.<\/li>\n\n\n\n<li><strong>Seating torque<\/strong> is the force needed to close and seat the valve completely. While this is slightly increased for ball valves, it can do so considerably for resilient seated butterfly valves.  <\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Additional Factors That Impact Torque Requirements <\/h3>\n\n\n\n<p>Several application or system-specific variables can also influence torque requirements\u2014some of which engineers and buyers often overlook. Here are the most critical ones to consider:<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Media Type and Process Conditions<\/h4>\n\n\n\n<p>Different media can dramatically affect torque requirements. For instance:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Dry gases<\/strong> lack lubricating properties, often increasing break torque.<\/li>\n\n\n\n<li><strong>Slurries and viscous fluids<\/strong> demand more force to ensure a complete seal on closing.<\/li>\n\n\n\n<li><strong>Fibrous or particulate media<\/strong> can create intermittent resistance that the actuator must overcome.<\/li>\n<\/ul>\n\n\n\n<p>A higher safety factor is often advisable when working with potentially hazardous or corrosive media. It\u2019s not just about valve function\u2014it\u2019s about ensuring safe operation under worst-case conditions. Electric actuators must be NEMA rated for the area classification (E.G. Nema 4, 4X, 6, 7, etc.).<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Air Supply Pressure<\/h4>\n\n\n\n<p>Pneumatic actuators rely on consistent air pressure to generate torque. Assured Automation typically sizes actuators for <strong>60 or 80 psi<\/strong>, which aligns with most industrial air systems. But if the supply pressure fluctuates\u2014or drops below spec\u2014the actuator might not deliver the torque you expected. That\u2019s why a <strong>minimum 20% safety factor<\/strong> is typically built in, then adjusted upward if the other attributes of the application demand it.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Mounting Compatibility<\/h3>\n\n\n\n<p>Adhering to <a href=\"https:\/\/cdn.standards.iteh.ai\/samples\/62594\/99f2c2aed9e24049bf1985c541d19143\/ISO-5211-2017.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">ISO 5211 standards<\/a> is key to ensuring actuator and valve compatibility. Most components have dual- or even triple-patterned  standard bolt circles to accommodate multiple sizes. Making sure that the valve and actuator share a common bolt pattern is the key for the direct mount connection. <\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Additional Mounting Hardware<\/h4>\n\n\n\n<p>In addition to matching the bolt circles, the stem shape, size, and height must mate properly. If a mismatch occurs, the actuator won\u2019t fit\u2014or worse, an improper fit could cause \u201cslop\u201d or &#8220;play&#8221; between components, leading to incomplete travel, stem or socket wear, and eventually failure due to stripping. Selecting correctly sized <strong>inserts<\/strong>, <strong>reducers, <\/strong>and <strong>couplings<\/strong> is critical to ensuring a tight, proper fit. That&#8217;s another aspect you won&#8217;t have to worry about when using Assured Automation&#8217;s <a href=\"https:\/\/assuredautomation.com\/videos\/index.php?vid=48&amp;p=video_player\">actuated valve configurators<\/a>.<\/p>\n\n\n\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-6c531013 wp-block-group-is-layout-flex\">\n<img decoding=\"async\" src=\"\/SVGs\/ISO5211.svg\" style=\"width:100%;\" \/>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2025\/05\/patterns-and-reducers-copy-1024x768.webp\" alt=\"\" class=\"wp-image-9030\" srcset=\"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2025\/05\/patterns-and-reducers-copy-1024x768.webp 1024w, https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2025\/05\/patterns-and-reducers-copy-300x225.webp 300w, https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2025\/05\/patterns-and-reducers-copy-768x576.webp 768w, https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2025\/05\/patterns-and-reducers-copy.webp 1080w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-6c531013 wp-block-group-is-layout-flex\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Common Sizing Mistakes (And Their Consequences)<\/h2>\n\n\n\n<p>Under-sizing is the most frequent mistake due to skipping safety factors, misjudging break torque, ignoring media effects or other special conditions. This can cause incomplete valve actuation or failure under load.<\/p>\n\n\n\n<p>Another issue is the incorrect actuator type or configuration. Some forget that spring-return torque decreases at end stroke or that scotch yoke actuators deliver non-linear torque. Start, mid-stroke, and end torque values can be drastically different.<\/p>\n\n\n\n<p>Mechanical mismatches like stem misalignment or incorrect ISO pattern mounting can cause excessive wear or assembly failure. Even over-sizing has consequences: excessive air use, slow cycles, or overly complex mounting.<\/p>\n\n\n\n<p>These are avoidable with the right tools and expertise.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Special Considerations in Harsh or Complex Environments<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Hazardous Locations:<\/strong> Use of explosion-proof, NEMA rated electric actuators, solenoid valves, and feedback switches are required in flammable environments. Torque requirements will remain the same, but electrical specifications change.<\/li>\n\n\n\n<li><strong>Extreme Temperatures:<\/strong> Affect seals, lubrication, and performance. Choose actuators rated for your conditions.<\/li>\n<\/ul>\n\n\n\n<p>As you can see, quarter-turn valve actuator selection and sizing isn\u2019t just about hitting a torque value. It\u2019s also about accounting for line pressure, stroke dynamics, and mechanical compatibility to ensure the valve opens and closes as intended\u2014every single time.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">How Assured Automation Simplifies the Sizing Process<\/h2>\n\n\n\n<p>Use our <a href=\"https:\/\/assuredautomation.com\/valve-configurators\/configurators.php\">online configurators for standard applications<\/a>\u2014 select valve size, actuator type, and air pressure. The system handles the rest, including hardware selection.<\/p>\n\n\n\n<p>Our team steps in when conditions are unusual\u2014viscous media, fluctuating pressure, and special certifications. We match torque, patterns, and hardware to your specifications and deliver pre-assembled solutions ready to install.<\/p>\n\n\n\n<p><em>We make <strong>valve automation<\/strong> easy!<\/em> by combining tools, experience, and support.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Key Takeaways:<\/h2>\n\n\n\n<p>Correct actuator sizing impacts system cost, performance, efficiency, and reliability. <\/p>\n\n\n\n<p><strong>Avoid common pitfalls by considering:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Break and seating torque \u2014 not just running torque<\/li>\n\n\n\n<li>Air pressure variation and safety margins<\/li>\n\n\n\n<li>Actuator torque curve types<\/li>\n\n\n\n<li>Media substance and conditions<\/li>\n\n\n\n<li>Mounting compatibility (ISO 5211)<\/li>\n<\/ul>\n\n\n\n<p>For more help, refer to our <strong><a href=\"https:\/\/assuredautomation.com\/valve-actuators\/\">Valve Actuators &#8211; Quarter-turn Selection Guide<\/a><\/strong> or speak with our engineering support team. Assured Automation offers live support via online Chat or Phone during Normal Business Hours EST. <\/p>\n\n\n\n<p>For standard actuated valve packages, use <a href=\"https:\/\/assuredautomation.com\/videos\/index.php?vid=48&amp;p=video_player\">our interactive valve configurators.<\/a> <\/p>\n\n\n\n<p>For complex needs, contact us\u2014we\u2019ll help you get it right!<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Call <strong><a href=\"tel:8008990553\">1-800-899-0553<\/a><\/strong><\/li>\n\n\n\n<li><strong>Download our Pneumatic Actuator Brochures<\/strong>\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/assuredautomation.com\/C-pneumatic-actuators\/\"><strong>C series<\/strong> Rack-n-pinion<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/assuredautomation.com\/F-pneumatic-actuators\/\"><strong>F Series<\/strong> Rack-n-Pinion<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/assuredautomation.com\/P-pneumatic-actuators\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>P Series<\/strong> Scotch Yoke<\/a><\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"https:\/\/assuredautomation.com\/C-pneumatic-actuators\/index.php?p=buy\">Buy C Series Rack &amp; Pinion Pneumatic Valve Actuators<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/assuredautomation.com\/F-pneumatic-actuators\/index.php?p=buy\">Buy F Series Rack &amp; Pinion Pneumatic Valve Actuators<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/assuredautomation.com\/P-pneumatic-actuators\/index.php?p=buy\">Buy P Series Dual Scotch Yoke Pneumatic Valve Actuators<\/a><\/li>\n<\/ul>\n\n\n\n<p><strong>Remember<\/strong>\u2014We Make <strong>Valve Automation <\/strong>Easy.<\/p>\n\n\n<div style=\"background-color:#f6f6f6; font-size:clamp(0.875rem, 0.875rem + ((1vw - 0.2rem) * 0.773), 1.3rem);font-style:normal;font-weight:400;line-height:1.8; border-radius:10px; padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--30);padding-right:var(--wp--preset--spacing--30);margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30);\" class=\"wp-block-post-author has-background\"><div class=\"wp-block-post-author__avatar\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2026\/03\/BB-Photo2026.jpg\" width=\"75\" height=\"96\" srcset=\"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2026\/03\/BB-Photo2026.jpg 2x\" alt=\"Brian Booth\" class=\"avatar avatar-96 wp-user-avatar wp-user-avatar-96 alignnone photo\" \/><\/div><div class=\"wp-block-post-author__content\"><p class=\"wp-block-post-author__byline\">Vice President of Sales<\/p><p class=\"wp-block-post-author__name\">Brian Booth<\/p><p class=\"wp-block-post-author__bio\">Brian Booth is the Vice President of Business Development and leads the sales team at Assured Automation\u2014a leading provider of Automated Valves, Flow Components, and Fire Safety Products for industrial process control applications. <a href=\"https:\/\/assuredautomation.com\/contact.php\">Contact Us.<\/a><\/p><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Actuator sizing for quarter-turn valves may seem simple, but there\u2019s a bit more to it than just matching torque values from a chart against the torque values required by the valve. In fact, it\u2019s one of the most common areas where engineers and buyers make critical mistakes. At Assured Automation, we\u2019ve helped customers navigate these [&hellip;]<\/p>\n","protected":false},"author":11185,"featured_media":8952,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[5,652],"tags":[],"class_list":["post-8903","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-automatednews","category-valve-actuators"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Actuator Sizing for Quarter-Turn Valves: Practical Guide<\/title>\n<meta name=\"description\" content=\"Learn how to get actuator sizing for quarter-turn valves actuator sizing right. Avoid costly mistakes with this expert guide.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/assuredautomation.com\/news-and-training\/simplifying-actuator-sizing-for-quarter-turn-valves-a-practical-guide\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Actuator Sizing for Quarter-Turn Valves: Practical Guide\" \/>\n<meta property=\"og:description\" content=\"Learn how to get actuator sizing for quarter-turn valves actuator sizing right. Avoid costly mistakes with this expert guide.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/assuredautomation.com\/news-and-training\/simplifying-actuator-sizing-for-quarter-turn-valves-a-practical-guide\/\" \/>\n<meta property=\"og:site_name\" content=\"Assured Automation\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/AssuredAutomation\" \/>\n<meta property=\"article:published_time\" content=\"2025-04-16T18:41:27+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-08-20T00:40:04+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2025\/04\/Sizing-Actuators.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Brian Booth\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@aaValvesMeters\" \/>\n<meta name=\"twitter:site\" content=\"@aaValvesMeters\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Brian Booth\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"8 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/simplifying-actuator-sizing-for-quarter-turn-valves-a-practical-guide\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/simplifying-actuator-sizing-for-quarter-turn-valves-a-practical-guide\\\/\"},\"author\":{\"name\":\"Brian Booth\",\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/#\\\/schema\\\/person\\\/80784d33bcf92ca0f343b63ad139b6ba\"},\"headline\":\"Simplifying Actuator Sizing for Quarter-Turn Valves: A Practical Guide\",\"datePublished\":\"2025-04-16T18:41:27+00:00\",\"dateModified\":\"2025-08-20T00:40:04+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/simplifying-actuator-sizing-for-quarter-turn-valves-a-practical-guide\\\/\"},\"wordCount\":1483,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/simplifying-actuator-sizing-for-quarter-turn-valves-a-practical-guide\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/Sizing-Actuators.jpg\",\"articleSection\":[\"Latest News\",\"Valve Actuators\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/simplifying-actuator-sizing-for-quarter-turn-valves-a-practical-guide\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/simplifying-actuator-sizing-for-quarter-turn-valves-a-practical-guide\\\/\",\"url\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/simplifying-actuator-sizing-for-quarter-turn-valves-a-practical-guide\\\/\",\"name\":\"Actuator Sizing for Quarter-Turn Valves: Practical Guide\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/simplifying-actuator-sizing-for-quarter-turn-valves-a-practical-guide\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/simplifying-actuator-sizing-for-quarter-turn-valves-a-practical-guide\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/Sizing-Actuators.jpg\",\"datePublished\":\"2025-04-16T18:41:27+00:00\",\"dateModified\":\"2025-08-20T00:40:04+00:00\",\"description\":\"Learn how to get actuator sizing for quarter-turn valves actuator sizing right. Avoid costly mistakes with this expert guide.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/simplifying-actuator-sizing-for-quarter-turn-valves-a-practical-guide\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/simplifying-actuator-sizing-for-quarter-turn-valves-a-practical-guide\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/simplifying-actuator-sizing-for-quarter-turn-valves-a-practical-guide\\\/#primaryimage\",\"url\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/Sizing-Actuators.jpg\",\"contentUrl\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/Sizing-Actuators.jpg\",\"width\":1000,\"height\":600},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/simplifying-actuator-sizing-for-quarter-turn-valves-a-practical-guide\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Simplifying Actuator Sizing for Quarter-Turn Valves: A Practical Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/#website\",\"url\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/\",\"name\":\"Assured Automation\",\"description\":\"Automated and Actuated Valves News and Training\",\"publisher\":{\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/#organization\",\"name\":\"Assured Automation\",\"url\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/wp-content\\\/uploads\\\/2015\\\/03\\\/AA_logo.gif\",\"contentUrl\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/wp-content\\\/uploads\\\/2015\\\/03\\\/AA_logo.gif\",\"width\":201,\"height\":51,\"caption\":\"Assured Automation\"},\"image\":{\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/AssuredAutomation\",\"https:\\\/\\\/x.com\\\/aaValvesMeters\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/assured-automation\",\"https:\\\/\\\/youtube.com\\\/user\\\/assuredautomation\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/#\\\/schema\\\/person\\\/80784d33bcf92ca0f343b63ad139b6ba\",\"name\":\"Brian Booth\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/BB-Photo2026.jpg\",\"url\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/BB-Photo2026.jpg\",\"contentUrl\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/BB-Photo2026.jpg\",\"caption\":\"Brian Booth\"},\"description\":\"Brian Booth is the Vice President of Business Development and leads the sales team at Assured Automation\u2014a leading provider of Automated Valves, Flow Components, and Fire Safety Products for industrial process control applications. Contact Us.\",\"sameAs\":[\"https:\\\/\\\/assuredautomation.com\\\/\"],\"url\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/author\\\/brian-booth\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Actuator Sizing for Quarter-Turn Valves: Practical Guide","description":"Learn how to get actuator sizing for quarter-turn valves actuator sizing right. Avoid costly mistakes with this expert guide.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/assuredautomation.com\/news-and-training\/simplifying-actuator-sizing-for-quarter-turn-valves-a-practical-guide\/","og_locale":"en_US","og_type":"article","og_title":"Actuator Sizing for Quarter-Turn Valves: Practical Guide","og_description":"Learn how to get actuator sizing for quarter-turn valves actuator sizing right. Avoid costly mistakes with this expert guide.","og_url":"https:\/\/assuredautomation.com\/news-and-training\/simplifying-actuator-sizing-for-quarter-turn-valves-a-practical-guide\/","og_site_name":"Assured Automation","article_publisher":"https:\/\/www.facebook.com\/AssuredAutomation","article_published_time":"2025-04-16T18:41:27+00:00","article_modified_time":"2025-08-20T00:40:04+00:00","og_image":[{"width":1000,"height":600,"url":"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2025\/04\/Sizing-Actuators.jpg","type":"image\/jpeg"}],"author":"Brian Booth","twitter_card":"summary_large_image","twitter_creator":"@aaValvesMeters","twitter_site":"@aaValvesMeters","twitter_misc":{"Written by":"Brian Booth","Est. reading time":"8 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/assuredautomation.com\/news-and-training\/simplifying-actuator-sizing-for-quarter-turn-valves-a-practical-guide\/#article","isPartOf":{"@id":"https:\/\/assuredautomation.com\/news-and-training\/simplifying-actuator-sizing-for-quarter-turn-valves-a-practical-guide\/"},"author":{"name":"Brian Booth","@id":"https:\/\/assuredautomation.com\/news-and-training\/#\/schema\/person\/80784d33bcf92ca0f343b63ad139b6ba"},"headline":"Simplifying Actuator Sizing for Quarter-Turn Valves: A Practical Guide","datePublished":"2025-04-16T18:41:27+00:00","dateModified":"2025-08-20T00:40:04+00:00","mainEntityOfPage":{"@id":"https:\/\/assuredautomation.com\/news-and-training\/simplifying-actuator-sizing-for-quarter-turn-valves-a-practical-guide\/"},"wordCount":1483,"commentCount":0,"publisher":{"@id":"https:\/\/assuredautomation.com\/news-and-training\/#organization"},"image":{"@id":"https:\/\/assuredautomation.com\/news-and-training\/simplifying-actuator-sizing-for-quarter-turn-valves-a-practical-guide\/#primaryimage"},"thumbnailUrl":"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2025\/04\/Sizing-Actuators.jpg","articleSection":["Latest News","Valve Actuators"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/assuredautomation.com\/news-and-training\/simplifying-actuator-sizing-for-quarter-turn-valves-a-practical-guide\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/assuredautomation.com\/news-and-training\/simplifying-actuator-sizing-for-quarter-turn-valves-a-practical-guide\/","url":"https:\/\/assuredautomation.com\/news-and-training\/simplifying-actuator-sizing-for-quarter-turn-valves-a-practical-guide\/","name":"Actuator Sizing for Quarter-Turn Valves: Practical Guide","isPartOf":{"@id":"https:\/\/assuredautomation.com\/news-and-training\/#website"},"primaryImageOfPage":{"@id":"https:\/\/assuredautomation.com\/news-and-training\/simplifying-actuator-sizing-for-quarter-turn-valves-a-practical-guide\/#primaryimage"},"image":{"@id":"https:\/\/assuredautomation.com\/news-and-training\/simplifying-actuator-sizing-for-quarter-turn-valves-a-practical-guide\/#primaryimage"},"thumbnailUrl":"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2025\/04\/Sizing-Actuators.jpg","datePublished":"2025-04-16T18:41:27+00:00","dateModified":"2025-08-20T00:40:04+00:00","description":"Learn how to get actuator sizing for quarter-turn valves actuator sizing right. Avoid costly mistakes with this expert guide.","breadcrumb":{"@id":"https:\/\/assuredautomation.com\/news-and-training\/simplifying-actuator-sizing-for-quarter-turn-valves-a-practical-guide\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/assuredautomation.com\/news-and-training\/simplifying-actuator-sizing-for-quarter-turn-valves-a-practical-guide\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/assuredautomation.com\/news-and-training\/simplifying-actuator-sizing-for-quarter-turn-valves-a-practical-guide\/#primaryimage","url":"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2025\/04\/Sizing-Actuators.jpg","contentUrl":"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2025\/04\/Sizing-Actuators.jpg","width":1000,"height":600},{"@type":"BreadcrumbList","@id":"https:\/\/assuredautomation.com\/news-and-training\/simplifying-actuator-sizing-for-quarter-turn-valves-a-practical-guide\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/assuredautomation.com\/news-and-training\/"},{"@type":"ListItem","position":2,"name":"Simplifying Actuator Sizing for Quarter-Turn Valves: A Practical Guide"}]},{"@type":"WebSite","@id":"https:\/\/assuredautomation.com\/news-and-training\/#website","url":"https:\/\/assuredautomation.com\/news-and-training\/","name":"Assured Automation","description":"Automated and Actuated Valves News and Training","publisher":{"@id":"https:\/\/assuredautomation.com\/news-and-training\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/assuredautomation.com\/news-and-training\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/assuredautomation.com\/news-and-training\/#organization","name":"Assured Automation","url":"https:\/\/assuredautomation.com\/news-and-training\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/assuredautomation.com\/news-and-training\/#\/schema\/logo\/image\/","url":"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2015\/03\/AA_logo.gif","contentUrl":"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2015\/03\/AA_logo.gif","width":201,"height":51,"caption":"Assured Automation"},"image":{"@id":"https:\/\/assuredautomation.com\/news-and-training\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/AssuredAutomation","https:\/\/x.com\/aaValvesMeters","https:\/\/www.linkedin.com\/company\/assured-automation","https:\/\/youtube.com\/user\/assuredautomation"]},{"@type":"Person","@id":"https:\/\/assuredautomation.com\/news-and-training\/#\/schema\/person\/80784d33bcf92ca0f343b63ad139b6ba","name":"Brian Booth","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2026\/03\/BB-Photo2026.jpg","url":"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2026\/03\/BB-Photo2026.jpg","contentUrl":"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2026\/03\/BB-Photo2026.jpg","caption":"Brian Booth"},"description":"Brian Booth is the Vice President of Business Development and leads the sales team at Assured Automation\u2014a leading provider of Automated Valves, Flow Components, and Fire Safety Products for industrial process control applications. Contact Us.","sameAs":["https:\/\/assuredautomation.com\/"],"url":"https:\/\/assuredautomation.com\/news-and-training\/author\/brian-booth\/"}]}},"_links":{"self":[{"href":"https:\/\/assuredautomation.com\/news-and-training\/wp-json\/wp\/v2\/posts\/8903","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/assuredautomation.com\/news-and-training\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/assuredautomation.com\/news-and-training\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/assuredautomation.com\/news-and-training\/wp-json\/wp\/v2\/users\/11185"}],"replies":[{"embeddable":true,"href":"https:\/\/assuredautomation.com\/news-and-training\/wp-json\/wp\/v2\/comments?post=8903"}],"version-history":[{"count":37,"href":"https:\/\/assuredautomation.com\/news-and-training\/wp-json\/wp\/v2\/posts\/8903\/revisions"}],"predecessor-version":[{"id":9034,"href":"https:\/\/assuredautomation.com\/news-and-training\/wp-json\/wp\/v2\/posts\/8903\/revisions\/9034"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/assuredautomation.com\/news-and-training\/wp-json\/wp\/v2\/media\/8952"}],"wp:attachment":[{"href":"https:\/\/assuredautomation.com\/news-and-training\/wp-json\/wp\/v2\/media?parent=8903"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/assuredautomation.com\/news-and-training\/wp-json\/wp\/v2\/categories?post=8903"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/assuredautomation.com\/news-and-training\/wp-json\/wp\/v2\/tags?post=8903"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}