{"id":1377,"date":"2012-10-11T13:54:19","date_gmt":"2012-10-11T17:54:19","guid":{"rendered":"http:\/\/assuredautomation.com\/news-and-training\/?p=1377"},"modified":"2023-02-14T11:13:17","modified_gmt":"2023-02-14T16:13:17","slug":"determining-factors-in-choosing-pneumatic-vs-electric-actuators","status":"publish","type":"post","link":"https:\/\/assuredautomation.com\/news-and-training\/determining-factors-in-choosing-pneumatic-vs-electric-actuators\/","title":{"rendered":"Determining Factors in Choosing Pneumatic vs. Electric Actuators"},"content":{"rendered":"<h3><strong>Pneumatic vs Electric Actuators<\/strong><\/h3>\n<p>Since their technologies are so different, determining whether to choose a pneumatic or electric actuator for a process system may seem confusing.&nbsp;&nbsp; Typically, <a title=\"Assured Automation Electric Actuators\" href=\"\/valve-actuators\/index.php\">electric actuators <\/a>are known for their high levels of precision while <a title=\"Assured Automation Pneumatic actuators\" href=\"\/valve-actuators\/index.php#pneumatic-actuators\">pneumatic actuators <\/a>are considered less expensive and easier to maintain. &nbsp;Each technology has its inherent advantages and disadvantages and the criteria below should be considered to ensure the best actuator for the application is purchased.<\/p>\n<p><strong>1. Power Source- <\/strong>Determine the most effective power source for the actuator taking into account power source availability, torque at valve stem, failure mode, control accessories, speed of operation, plant environment and size of valve.<\/p>\n<figure id=\"attachment_1390\" aria-describedby=\"caption-attachment-1390\" style=\"width: 150px\" class=\"wp-caption alignright\"><a href=\"\/O-pneumatic-actuators\/index.php\"><img loading=\"lazy\" decoding=\"async\" class=\"size-thumbnail wp-image-1390\" title=\"O Series Pneumatic actuator\" src=\"\/news-and-training\/wp-content\/uploads\/2012\/10\/Oseries-actuator-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\"><\/a><figcaption id=\"caption-attachment-1390\" class=\"wp-caption-text\">O Series Pneumatic Actuator<\/figcaption><\/figure>\n<p>Most pneumatic air operators require an air pressure supply of 40 to 120 psi. Generally they are sized for a supply pressure of 60 to 80 psi. Higher air pressure is usually difficult to guarantee and lower pressures require a large diameter piston or diaphragm to generate usable torque.<\/p>\n<p>Most electric actuators require a 115 VAC or 24 VDC power supply, and are available in a variety of AC and DC motors in single phase and three phase.<\/p>\n<p><strong>2. Temperature Range- <\/strong><\/p>\n<p>Pneumatic actuators typically handle temperature ranges between -4 and 175\u00b0F but can reach -40 to 250\u00b0F with specialized seals and bearings. The quality of the supply air pressure in relation to dew point should be considered in low-temperature applications. (Dew point is the temperature at which condensation occurs in air) Condensate may freeze and block air supply lines, making the actuator inoperable.<\/p>\n<figure id=\"attachment_1389\" aria-describedby=\"caption-attachment-1389\" style=\"width: 150px\" class=\"wp-caption alignright\"><a href=\"\/K4-electric-actuators\/index.php\"><img loading=\"lazy\" decoding=\"async\" class=\"size-thumbnail wp-image-1389\" title=\"K4 electric actuator\" src=\"\/news-and-training\/wp-content\/uploads\/2012\/10\/K4-electric-actuator-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\"><\/a><figcaption id=\"caption-attachment-1389\" class=\"wp-caption-text\">K4 Electric Actuator<\/figcaption><\/figure>\n<p>Electric actuators operate best at temperatures between -40 and 150\u00b0F but are also subject to problems due to moisture and temperature.&nbsp; When used outdoors, electric actuators should be sealed from the environment to prevent moisture build up and subsequent potential damage. Even if properly sealed, condensation may still form, due to the heating and cooling of the enclosure from the motor\u2019s heat. Electric actuators used outdoors should have a heater and thermostat installed to maintain a constant temperature and eliminate condensation.<\/p>\n<p><strong>3. NEMA Guidelines-<\/strong><\/p>\n<p>Pneumatic actuators are inherently explosion proof and are a good choice in NEMA VII designated areas.<\/p>\n<p>If compressed air is not available or cannot provide the operation characteristics required then electric actuators may be used. Most electric actuator manufacturers have an enclosure option that conforms to Nema VII standards.<\/p>\n<p><strong>4. <\/strong><strong>Spring Return-<\/strong><\/p>\n<p>Spring return or fail-safe option is a widely specified safety feature on valve actuators. Upon power\/signal failure, a spring return actuator drives the valve to a predetermined safe position.&nbsp; Pneumatic actuators typically offer this inexpensive option while electric actuators are not widely available in a spring return version.<\/p>\n<p><strong>5. <\/strong><strong>Performance Characteristics-<\/strong><\/p>\n<p>When deciding between pneumatic or electric actuators, key performance characteristics such as duty cycle, stalling, speed control, modulating service and torque to weight ratio should also be taken into consideration.<\/p>\n<p><strong>Performance characteristics summary: <\/strong><\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"319\"><strong><em>Pneumatic<\/em><\/strong><\/td>\n<td valign=\"top\" width=\"319\"><strong><em>Electric<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"319\">Variable speed. Simple, accurate and inexpensive<\/td>\n<td valign=\"top\" width=\"319\">Fixed speed; pulsing circuit may be added<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"319\">Explosion proof, shock proof, spark proof<\/td>\n<td valign=\"top\" width=\"319\">Must be modified with NEMA enclosure for hazardous environment<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"319\">Not subject to overheating, not sensitive to wet environment<\/td>\n<td valign=\"top\" width=\"319\">Can overheat. Must be sealed from moisture.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"319\">100% duty cycle<\/td>\n<td valign=\"top\" width=\"319\">25% standard duty cycle. May be upgraded<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"319\">May be stalled indefinitely<\/td>\n<td valign=\"top\" width=\"319\">Cannot be stalled<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"319\">High torque to weight ratio<\/td>\n<td valign=\"top\" width=\"319\">Low torque to weight ratio<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"319\">Spring-return (fail-safe) option is practical and economical<\/td>\n<td valign=\"top\" width=\"319\">Spring-return option is generally unavailable<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><a href=\"\/news-and-training\/pneumatic-rotary-actuators-decision-tree\/\">See our Actuator Decision Tree<br \/>\n<\/a><a href=\"\/news-and-training\/pneumatic-rotary-actuators-decision-tree\/\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-5305 size-medium\" title=\"View a larger image of the electric vs. pneumatic actuator decision tree\" src=\"\/news-and-training\/wp-content\/uploads\/2016\/10\/Actuator-Decision-Tree-228x300.jpg\" alt=\"electric or pneumatic actuator decision tree\" width=\"228\" height=\"300\" srcset=\"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2016\/10\/Actuator-Decision-Tree-228x300.jpg 228w, https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2016\/10\/Actuator-Decision-Tree-768x1009.jpg 768w, https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2016\/10\/Actuator-Decision-Tree-780x1024.jpg 780w\" sizes=\"auto, (max-width: 228px) 100vw, 228px\" \/><\/a><\/p>\n<p>For assistance in sizing and specifying valve actuators call one of <a href=\"\/index.php\">Assured Automation\u2019s <\/a>highly trained sales associates at 1-800-899-0553 or email us at <a href=\"mailto:info@assuredautomation.com\">info@assuredautomation.com<\/a><\/p>\n<p><a href=\"\/literature\/valve_automation_ebook.php\"><img decoding=\"async\" class=\"aligncenter\" title=\"Request-Automated-Valves-Process-Control\" src=\"\/news-and-training\/images\/automated_valves_oxler.png\" alt=\"Request Automated Valves Process Control\"><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Pneumatic vs Electric Actuators Since their technologies are so different, determining whether to choose a pneumatic or electric actuator for a process system may seem confusing.&nbsp;&nbsp; Typically, electric actuators are known for their high levels of precision while pneumatic actuators are considered less expensive and easier to maintain. &nbsp;Each technology has its inherent advantages and [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":7415,"comment_status":"open","ping_status":"open","sticky":false,"template":"single-with-sidebar","format":"standard","meta":{"footnotes":""},"categories":[5],"tags":[54,64],"class_list":["post-1377","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-automatednews","tag-electric-actuators","tag-pneumatic-actuators"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Pneumatic vs Electric Actuators<\/title>\n<meta name=\"description\" content=\"Electric actuators are known for their high levels of precision. Pneumatic actuators are considered less expensive and easier to maintain.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/assuredautomation.com\/news-and-training\/determining-factors-in-choosing-pneumatic-vs-electric-actuators\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Pneumatic vs Electric Actuators\" \/>\n<meta property=\"og:description\" content=\"Electric actuators are known for their high levels of precision. Pneumatic actuators are considered less expensive and easier to maintain.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/assuredautomation.com\/news-and-training\/determining-factors-in-choosing-pneumatic-vs-electric-actuators\/\" \/>\n<meta property=\"og:site_name\" content=\"Assured Automation\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/AssuredAutomation\" \/>\n<meta property=\"article:published_time\" content=\"2012-10-11T17:54:19+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-02-14T16:13:17+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2013\/04\/K-Series-actuator.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"294\" \/>\n\t<meta property=\"og:image:height\" content=\"231\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Kim O&#039;Neill\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@aaValvesMeters\" \/>\n<meta name=\"twitter:site\" content=\"@aaValvesMeters\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Kim O&#039;Neill\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/determining-factors-in-choosing-pneumatic-vs-electric-actuators\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/determining-factors-in-choosing-pneumatic-vs-electric-actuators\\\/\"},\"author\":{\"name\":\"Kim O'Neill\",\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/#\\\/schema\\\/person\\\/6f2d78a7dedc326b0e8ca958b4621357\"},\"headline\":\"Determining Factors in Choosing Pneumatic vs. Electric Actuators\",\"datePublished\":\"2012-10-11T17:54:19+00:00\",\"dateModified\":\"2023-02-14T16:13:17+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/determining-factors-in-choosing-pneumatic-vs-electric-actuators\\\/\"},\"wordCount\":613,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/determining-factors-in-choosing-pneumatic-vs-electric-actuators\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/wp-content\\\/uploads\\\/2013\\\/04\\\/K-Series-actuator.jpg\",\"keywords\":[\"Electric Actuators\",\"Pneumatic Actuators\"],\"articleSection\":[\"Latest News\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/determining-factors-in-choosing-pneumatic-vs-electric-actuators\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/determining-factors-in-choosing-pneumatic-vs-electric-actuators\\\/\",\"url\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/determining-factors-in-choosing-pneumatic-vs-electric-actuators\\\/\",\"name\":\"Pneumatic vs Electric Actuators\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/determining-factors-in-choosing-pneumatic-vs-electric-actuators\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/determining-factors-in-choosing-pneumatic-vs-electric-actuators\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/wp-content\\\/uploads\\\/2013\\\/04\\\/K-Series-actuator.jpg\",\"datePublished\":\"2012-10-11T17:54:19+00:00\",\"dateModified\":\"2023-02-14T16:13:17+00:00\",\"description\":\"Electric actuators are known for their high levels of precision. Pneumatic actuators are considered less expensive and easier to maintain.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/determining-factors-in-choosing-pneumatic-vs-electric-actuators\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/determining-factors-in-choosing-pneumatic-vs-electric-actuators\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/determining-factors-in-choosing-pneumatic-vs-electric-actuators\\\/#primaryimage\",\"url\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/wp-content\\\/uploads\\\/2013\\\/04\\\/K-Series-actuator.jpg\",\"contentUrl\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/wp-content\\\/uploads\\\/2013\\\/04\\\/K-Series-actuator.jpg\",\"width\":294,\"height\":231},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/determining-factors-in-choosing-pneumatic-vs-electric-actuators\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Determining Factors in Choosing Pneumatic vs. Electric Actuators\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/#website\",\"url\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/\",\"name\":\"Assured Automation\",\"description\":\"Automated and Actuated Valves News and Training\",\"publisher\":{\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/#organization\",\"name\":\"Assured Automation\",\"url\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/wp-content\\\/uploads\\\/2015\\\/03\\\/AA_logo.gif\",\"contentUrl\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/wp-content\\\/uploads\\\/2015\\\/03\\\/AA_logo.gif\",\"width\":201,\"height\":51,\"caption\":\"Assured Automation\"},\"image\":{\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/AssuredAutomation\",\"https:\\\/\\\/x.com\\\/aaValvesMeters\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/assured-automation\",\"https:\\\/\\\/youtube.com\\\/user\\\/assuredautomation\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/#\\\/schema\\\/person\\\/6f2d78a7dedc326b0e8ca958b4621357\",\"name\":\"Kim O'Neill\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/869e1b1c2d2a9a83ed9f5af3fa75ab55c0738e139a417253a4a4bb6a784c4df0?s=96&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/869e1b1c2d2a9a83ed9f5af3fa75ab55c0738e139a417253a4a4bb6a784c4df0?s=96&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/869e1b1c2d2a9a83ed9f5af3fa75ab55c0738e139a417253a4a4bb6a784c4df0?s=96&r=g\",\"caption\":\"Kim O'Neill\"},\"description\":\"Marketing administrator at Assured Automation, a leading provider of automated valves and flow components for industrial process control applications. For over 30 years Assured Automation has provided state of the art automation to a diverse clientele ranging from small equipment manufacturers to Fortune 500 Manufacturing, Chemical and Pharmaceutical companies. The Assured Automation product line consists of a complete offering of standardized automated valve assemblies with a variety of commonly used accessory items. In addition, we offer complete valve automation services where we supply special automated valve assemblies designed around your specified products or your particular applications. Full design capabilities are offered including AutoCAD, Solidworks or other commonly used design and drawing programs. In addition to standard products, Assured Automation develops customized solutions for specific customer challenges. You can find Kim O'Neill on LinkedIn.\",\"sameAs\":[\"https:\\\/\\\/assuredautomation.com\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/kim-oneill-a1249344\\\/\",\"https:\\\/\\\/x.com\\\/aaValvesMeters\"],\"url\":\"https:\\\/\\\/assuredautomation.com\\\/news-and-training\\\/author\\\/kim\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Pneumatic vs Electric Actuators","description":"Electric actuators are known for their high levels of precision. Pneumatic actuators are considered less expensive and easier to maintain.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/assuredautomation.com\/news-and-training\/determining-factors-in-choosing-pneumatic-vs-electric-actuators\/","og_locale":"en_US","og_type":"article","og_title":"Pneumatic vs Electric Actuators","og_description":"Electric actuators are known for their high levels of precision. Pneumatic actuators are considered less expensive and easier to maintain.","og_url":"https:\/\/assuredautomation.com\/news-and-training\/determining-factors-in-choosing-pneumatic-vs-electric-actuators\/","og_site_name":"Assured Automation","article_publisher":"https:\/\/www.facebook.com\/AssuredAutomation","article_published_time":"2012-10-11T17:54:19+00:00","article_modified_time":"2023-02-14T16:13:17+00:00","og_image":[{"width":294,"height":231,"url":"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2013\/04\/K-Series-actuator.jpg","type":"image\/jpeg"}],"author":"Kim O'Neill","twitter_card":"summary_large_image","twitter_creator":"@aaValvesMeters","twitter_site":"@aaValvesMeters","twitter_misc":{"Written by":"Kim O'Neill","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/assuredautomation.com\/news-and-training\/determining-factors-in-choosing-pneumatic-vs-electric-actuators\/#article","isPartOf":{"@id":"https:\/\/assuredautomation.com\/news-and-training\/determining-factors-in-choosing-pneumatic-vs-electric-actuators\/"},"author":{"name":"Kim O'Neill","@id":"https:\/\/assuredautomation.com\/news-and-training\/#\/schema\/person\/6f2d78a7dedc326b0e8ca958b4621357"},"headline":"Determining Factors in Choosing Pneumatic vs. Electric Actuators","datePublished":"2012-10-11T17:54:19+00:00","dateModified":"2023-02-14T16:13:17+00:00","mainEntityOfPage":{"@id":"https:\/\/assuredautomation.com\/news-and-training\/determining-factors-in-choosing-pneumatic-vs-electric-actuators\/"},"wordCount":613,"commentCount":0,"publisher":{"@id":"https:\/\/assuredautomation.com\/news-and-training\/#organization"},"image":{"@id":"https:\/\/assuredautomation.com\/news-and-training\/determining-factors-in-choosing-pneumatic-vs-electric-actuators\/#primaryimage"},"thumbnailUrl":"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2013\/04\/K-Series-actuator.jpg","keywords":["Electric Actuators","Pneumatic Actuators"],"articleSection":["Latest News"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/assuredautomation.com\/news-and-training\/determining-factors-in-choosing-pneumatic-vs-electric-actuators\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/assuredautomation.com\/news-and-training\/determining-factors-in-choosing-pneumatic-vs-electric-actuators\/","url":"https:\/\/assuredautomation.com\/news-and-training\/determining-factors-in-choosing-pneumatic-vs-electric-actuators\/","name":"Pneumatic vs Electric Actuators","isPartOf":{"@id":"https:\/\/assuredautomation.com\/news-and-training\/#website"},"primaryImageOfPage":{"@id":"https:\/\/assuredautomation.com\/news-and-training\/determining-factors-in-choosing-pneumatic-vs-electric-actuators\/#primaryimage"},"image":{"@id":"https:\/\/assuredautomation.com\/news-and-training\/determining-factors-in-choosing-pneumatic-vs-electric-actuators\/#primaryimage"},"thumbnailUrl":"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2013\/04\/K-Series-actuator.jpg","datePublished":"2012-10-11T17:54:19+00:00","dateModified":"2023-02-14T16:13:17+00:00","description":"Electric actuators are known for their high levels of precision. Pneumatic actuators are considered less expensive and easier to maintain.","breadcrumb":{"@id":"https:\/\/assuredautomation.com\/news-and-training\/determining-factors-in-choosing-pneumatic-vs-electric-actuators\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/assuredautomation.com\/news-and-training\/determining-factors-in-choosing-pneumatic-vs-electric-actuators\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/assuredautomation.com\/news-and-training\/determining-factors-in-choosing-pneumatic-vs-electric-actuators\/#primaryimage","url":"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2013\/04\/K-Series-actuator.jpg","contentUrl":"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2013\/04\/K-Series-actuator.jpg","width":294,"height":231},{"@type":"BreadcrumbList","@id":"https:\/\/assuredautomation.com\/news-and-training\/determining-factors-in-choosing-pneumatic-vs-electric-actuators\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/assuredautomation.com\/news-and-training\/"},{"@type":"ListItem","position":2,"name":"Determining Factors in Choosing Pneumatic vs. Electric Actuators"}]},{"@type":"WebSite","@id":"https:\/\/assuredautomation.com\/news-and-training\/#website","url":"https:\/\/assuredautomation.com\/news-and-training\/","name":"Assured Automation","description":"Automated and Actuated Valves News and Training","publisher":{"@id":"https:\/\/assuredautomation.com\/news-and-training\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/assuredautomation.com\/news-and-training\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/assuredautomation.com\/news-and-training\/#organization","name":"Assured Automation","url":"https:\/\/assuredautomation.com\/news-and-training\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/assuredautomation.com\/news-and-training\/#\/schema\/logo\/image\/","url":"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2015\/03\/AA_logo.gif","contentUrl":"https:\/\/assuredautomation.com\/news-and-training\/wp-content\/uploads\/2015\/03\/AA_logo.gif","width":201,"height":51,"caption":"Assured Automation"},"image":{"@id":"https:\/\/assuredautomation.com\/news-and-training\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/AssuredAutomation","https:\/\/x.com\/aaValvesMeters","https:\/\/www.linkedin.com\/company\/assured-automation","https:\/\/youtube.com\/user\/assuredautomation"]},{"@type":"Person","@id":"https:\/\/assuredautomation.com\/news-and-training\/#\/schema\/person\/6f2d78a7dedc326b0e8ca958b4621357","name":"Kim O'Neill","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/869e1b1c2d2a9a83ed9f5af3fa75ab55c0738e139a417253a4a4bb6a784c4df0?s=96&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/869e1b1c2d2a9a83ed9f5af3fa75ab55c0738e139a417253a4a4bb6a784c4df0?s=96&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/869e1b1c2d2a9a83ed9f5af3fa75ab55c0738e139a417253a4a4bb6a784c4df0?s=96&r=g","caption":"Kim O'Neill"},"description":"Marketing administrator at Assured Automation, a leading provider of automated valves and flow components for industrial process control applications. For over 30 years Assured Automation has provided state of the art automation to a diverse clientele ranging from small equipment manufacturers to Fortune 500 Manufacturing, Chemical and Pharmaceutical companies. The Assured Automation product line consists of a complete offering of standardized automated valve assemblies with a variety of commonly used accessory items. In addition, we offer complete valve automation services where we supply special automated valve assemblies designed around your specified products or your particular applications. Full design capabilities are offered including AutoCAD, Solidworks or other commonly used design and drawing programs. In addition to standard products, Assured Automation develops customized solutions for specific customer challenges. You can find Kim O'Neill on LinkedIn.","sameAs":["https:\/\/assuredautomation.com","https:\/\/www.linkedin.com\/in\/kim-oneill-a1249344\/","https:\/\/x.com\/aaValvesMeters"],"url":"https:\/\/assuredautomation.com\/news-and-training\/author\/kim\/"}]}},"_links":{"self":[{"href":"https:\/\/assuredautomation.com\/news-and-training\/wp-json\/wp\/v2\/posts\/1377","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/assuredautomation.com\/news-and-training\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/assuredautomation.com\/news-and-training\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/assuredautomation.com\/news-and-training\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/assuredautomation.com\/news-and-training\/wp-json\/wp\/v2\/comments?post=1377"}],"version-history":[{"count":16,"href":"https:\/\/assuredautomation.com\/news-and-training\/wp-json\/wp\/v2\/posts\/1377\/revisions"}],"predecessor-version":[{"id":7471,"href":"https:\/\/assuredautomation.com\/news-and-training\/wp-json\/wp\/v2\/posts\/1377\/revisions\/7471"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/assuredautomation.com\/news-and-training\/wp-json\/wp\/v2\/media\/7415"}],"wp:attachment":[{"href":"https:\/\/assuredautomation.com\/news-and-training\/wp-json\/wp\/v2\/media?parent=1377"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/assuredautomation.com\/news-and-training\/wp-json\/wp\/v2\/categories?post=1377"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/assuredautomation.com\/news-and-training\/wp-json\/wp\/v2\/tags?post=1377"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}