Live
Loading stem sealing
Disc Plate & Belleville Washer - The disc plate uniformly compresses
the pair of Belleville washers to store energy for live loading.
Live loading extends the time required between maintenance.
Three
stages of stem sealing for
effective control of stem leakage
1. Pyramidal body and stem seal 1st stage Internal
Pressure of the valve pushes the pyramidal stem sealing upward.
Because of its shape, the sealing expands to fill all the air
pockets that might become a potential leakage path in the lower
stem area. Viton O-Ring 2nd stage The elastic nature of the
2.
Viton® O-Ring serves as an effective sealing for gaseous
medium that might escape the 1st stage sealing.
3.
V-Ring Stem Packing 3rd stage Live loading action of the Bellville
washer expands the V-Ring stem packing, filling all the air
pockets in the outer stem area. It effectively seals internal
media within as well as keeping out external media from entering
the system.
Independent
Stem Rotation
The rotational movement of the stem is independent of Disc Plate
and Belleville washers, the live loading system. The action
of stem rotation does not disrupt the sealing tightness of the
Disc Plate. During high cycle operation, the live loading system
works independently to maintain sealing integrity.
|